ECP 2.0 firmware
Download
Version
2.0
Released
May 15, 2014
To resolve an intermittent issue with system control, the Extended Control Panel (ECP) used with SMART Board 800 series interactive whiteboards and the SMART UX80 projector requires firmware version 2.0 or above. This firmware version addresses unresponsive control issues reported by some customers.
Ensure that your computer has a USB data connection to the primary USB port (marked with a desktop computer icon) on the back of the ECP.
Download the firmware on this page.
Move the BIN file (
0057-2.0.1.0-app.bin) to the appropriate folder location on your computer:Education software on 64-bit Windows operating systems
CopyC:\Program Files (x86)\SMART Technologies\Education Software\Firmware\SP2Education software on 32-bit Windows operating systems
CopyC:\Program Files\SMART Technologies\Education Software\Firmware\SP2Enterprise software on 64-bit Windows operating systems
CopyC:\Program Files (x86)\SMART Technologies\SMART Product Drivers\Firmware\SP2Enterprise software on 32-bit Windows operating systems
CopyC:\Program Files\SMART Technologies\SMART Product Drivers\Firmware\SP2Mac OS operating system software
CopyApplications > SMART Technologies > Firmware > SP2
Browse to the SMART Firmware Updater application:
Education software on 64-bit Windows operating systems
CopyC:\Program Files (x86)\SMART Technologies\Education Software\SMARTFirmwareUpdater.exeEducation software on 32-bit Windows operating systems
CopyC:\Program Files\SMART Technologies\Education Software\ SMARTFirmwareUpdater.exeEnterprise software on 64-bit Windows operating systems
CopyC:\Program Files (x86)\SMART Technologies\Meeting Pro Software\ SMARTFirmwareUpdater.exeEnterprise software on 32-bit Windows operating systems
CopyC:\Program Files\SMART Technologies\Meeting Pro Software\ SMARTFirmwareUpdater.exeMac OS operating system software
CopyApplications > SMART Technologies > SMART Tools > Firmware Updater
Note
Your SMART Board interactive whiteboard does not respond to touch while the firmware updater is running. You need a mouse device to complete the installation.
Run SMART Firmware Updater.
The SMART firmware updater displays the model and the current version for the SC14 control panel. If the Current Version is below 2.0, you need to update your SMART ECP firmware.
Select the SC14 Control Panel, click Next and then follow the onscreen instructions.
Close the updater after the firmware update is complete.